HS-PV
Star the Force
Availability: | |
---|---|
Product Description
Parameters
lectrical Specifications | |||||||||||||
| Model HS-PV | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |||
Inverter | rated power | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |||
Peak power | 3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||||
Output voltage | Pure sine wave (mains or generator) | ||||||||||||
Rated efficiency | >88%(Peak) | ||||||||||||
Online mode | >95% | ||||||||||||
Power factor | 0.9- 1.0 | ||||||||||||
Rated output | 100- 110- 120Vac / 220-230-240Vac | ||||||||||||
Output frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||||
Short circuit | Yes, protection after 1 second short circuit | ||||||||||||
| protection |
| |||||||||||
Typical switching | 10ms (maximum) | ||||||||||||
Total harmonic | < 10% | ||||||||||||
DC | Rated input | 12.0Vdc / 24.0Vdc | 24.0Vdc / 48.0Vdc | 48.0Vdc/60.0Vdc/72.0Vdc | |||||||||
Minimum starting | 10.0Vdc / 10.5Vdc for | *2 for 24Vdc,*4 for 48Vdc*5 | |||||||||||
Low battery | 10.5Vdc / 11.0Vdc for | ||||||||||||
Low voltage cut | 10.0Vdc / 10.5Vdc for | ||||||||||||
High voltage | 16.0Vdc for 12Vdc Mode | ||||||||||||
Low voltage | 15.5Vdc for 12Vdc Mode | ||||||||||||
Protect | Rated input | 100- 110- 120Vac / 220-230-240Vac | |||||||||||
Maximum input | 150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | ||||||||||||
Rated input | 50Hz or 60Hz | ||||||||||||
Low frequency | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||||
High frequency | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||||
Overload | yes | ||||||||||||
Output short | yes | ||||||||||||
Maximum bypass | 30Amp | 40Amp | 80Amp | ||||||||||
Charge | The output | Depends on battery type | |||||||||||
Charging circuit | 15A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||||
Maximum | See detailed table | ||||||||||||
| Starting voltage | 10.5- 15.7Vdc for | *2 for 24Vdc, *4 for 48Vdc;*6 72Vdc | ||||||||||
Overcharge | more than the 15.8Vdc for | ||||||||||||
Solar | Solar system | MPPT12V/24V/36V/48V automatic recognition | |||||||||||
Open circuit | 18~150Vdc@12V 35~150Vdc@24V 60~150Vdc@48V | ||||||||||||
Rated charging | 30A- 120A (optional) | ||||||||||||
Charging | 97.6% | ||||||||||||
Rechargeable | Valve-regulated lead-acid battery Gel battery Lithium battery | ||||||||||||
charging method | Four-stage charging: constant current charge, constant voltage charge, float charge, | ||||||||||||
safety protection | Solar panel short circuit protection, overcharge protection, over discharge protection, | ||||||||||||
| PV module | 12V/24V/48V | W99. 97% | ||||||||||
Input Features | |||||||||||||
MPPT working | 12V | DC18V-DC150V | |||||||||||
24V | DC34V-DC150V | ||||||||||||
48V | DC65V-DC150V | ||||||||||||
Max PV input | 12V/24V/48V | DC170V | |||||||||||
Over voltage | 12V/24V/48V | DC175V | |||||||||||
Over voltage input | 12V/24V/48V | DC170V | |||||||||||
MAX solar input | 12V System | 420W | 570W | 700W | 900W | 1140W | 1400W | ||||||
24V System | 840W | 1130W | 1400W | 1700W | 2260W | 2600W | |||||||
48V System | 1650W | 2270W | 2800W | 3400W | 4540W | 5600W | |||||||
Output Features | Same as battery voltage | ||||||||||||
| Battery Type(The | 12V/24V/48V/96V | Lead-acid maintenance-free batteries, gel batteries, | ||||||||||
Mechanical | Install | Wall mount | |||||||||||
Inverter size | 340*420 | 425*375*200mm | 560*420*235mm | 655*490*240mm | |||||||||
Inverter shell size | 415*440 | 500*495*300mm | 660*470*310mm | 720*470*290mm | |||||||||
Net weight of | 16 | 21.5 | 28.2 | 33 | 35.5 | 38 | 58 | 60.5 | 63 | ||||
Package includes | 19 | 24 | 30.8 | 39.5 | 42 | 45 | 65.5 | 67 | 70.5 | ||||
show | Status LEDs / Status LEDs+LCD | ||||||||||||
Standard warranty | 2 year |
Details